ON-OFF Automation Kit for Valves with IO-Link | PROFINET EtherNet/IP EtherCAT | All-or-Nothing Control
Pickup availability could not be loaded
ON-OFF Automation Kit for Valves with IO-Link — All-or-Nothing Control, Predictive Diagnostics, using a Single Cable Compatible with PROFINET EtherNet/IP EtherCAT
Cematic's ON-OFF automation kit for IO-Link valves is the solution for all-or-nothing automation of ball and butterfly valves in industrial facilities with PROFINET, EtherNet/IP, or EtherCAT networks. Unlike conventional analog positioners, this kit operates in all-or-nothing mode — fully open or fully closed — with digital position confirmation and integrated predictive diagnostics.
It is the correct specification when the process only requires opening or closing, since ON-OFF control is simpler and more economical than modulating control. Its IO-Link communication simultaneously transmits the ON-OFF control signal, diagnostic data, and power through a single standard cable, radically simplifying wiring compared to conventional analog solutions.
The integrated predictive diagnostics also detect actuator deterioration before it affects the process.
ON-OFF vs. modulating — why all-or-nothing control is the correct specification for shut-off valves
The distinction between ON-OFF and modulating automation is the most important criterion when selecting the kit. The following cases describe when ON-OFF is the correct specification:
- Shut-off and isolation valves where only two positions are required — since ON-OFF is sufficient and more economical: Most process valves — line shut-off, equipment isolation, flow diversion — only need to be fully open or fully closed. The ON-OFF kit is the correct specification in those cases, since modulating control would add cost and complexity without providing any functional benefit.
- PID control loops where the valve acts as the final control element, given that PID requires continuous regulation: The PID controller generates a continuous output signal proportional to the error between the actual and setpoint values.
The modulating positioner receives that signal and positions the valve precisely. It is also the standard component in advanced process control systems where control quality depends on the positioner's response.
- Modernization of manual valves where automatic control with diagnostics is required — since IO-Link provides more than a conventional switch: When a manual valve needs to be automated, the IO-Link ON-OFF kit provides position confirmation, predictive diagnostics, and digital communication to the PLC. Unlike a simple limit switch, it also transmits temperature data, operating hours, and accumulated cycles without additional wiring.
IO-Link — why a single cable outperforms conventional analog wiring even though both use IO-Link as a protocol
IO-Link communication is the technological differentiator of this kit compared to conventional limit switches. Therefore, it provides diagnostics and traceability that a standard switch cannot offer. Its advantages are described below:
- A single cable for signal, diagnostics, and power — since IO-Link is an all-in-one digital protocol: The analog positioner requires separate cables for the control signal, position feedback, and power. IO-Link transmits everything through a single standard cable. Consequently, it reduces the number of cables, PLC inputs/outputs, and field installation hours.
- Real-time predictive diagnostics — since the positioner transmits hours, temperature, cycles, and deviation to the PLC: The positioner continuously monitors the valve's operating parameters. When any value deviates from the normal range, it generates an alert event code in the PLC. The maintenance team can therefore detect deterioration before the valve fails, moving from reactive to predictive maintenance.
- No manual position adjustment — since the device automatically detects the open and closed positions: Unlike mechanical limit switches that require manual adjustment of the cam or flag, this kit automatically detects the actuator positions. Likewise, it requires no special tools or specialized technician for commissioning.
- Compatible with PROFINET, EtherNet/IP, and EtherCAT — for integration with any PLC brand: The kit follows the international IO-Link standard and is compatible with IO-Link masters from major manufacturers. Therefore, it integrates with PLCs from any manufacturer without additional protocol converters.
Technical specifications defining the ON-OFF automation kit for valves with IO-Link
| Parameter | Value |
|---|---|
| Automation type | ON-OFF — fully open or fully closed |
| Communication technology | IO-Link — IEC 61131-9 standard digital protocol |
| Wiring | A single IO-Link cable (signal + diagnostics + power) |
| Compatible valves | Quarter-turn ball and butterfly valves |
| Transmitted data | Actual position, temperature, operating hours, diagnostics |
| Diagnostics | Real-time predictive — detailed event codes to the PLC |
| Self-calibration | No repeated processes required — autonomous |
| Compatible protocols | PROFINET — EtherNet/IP — EtherCAT |
ON-OFF IO-Link Kit vs. conventional limit switch — comparison table to select the correct one since they differ in diagnostics and wiring
| Criterion | Conventional limit switch | ON-OFF IO-Link Kit ← This product |
|---|---|---|
| Wiring | ⚠️ Separate cables for open position signal, closed position signal, and power | ✅ A single IO-Link cable — signal, diagnostics, and power in one |
| Remote diagnostics | ❌ Open/closed status only — no temperature, hours, or cycles | ✅ Continuous — position, temperature, hours, and alarms to the PLC in real time |
| Self-calibration | ⚠️ Manual cam or flag adjustment — requires a field technician | ✅ No manual adjustment required — automatically detects position |
| Signal type | Binary digital — only open or closed to the PLC | ✅ 100% digital — no noise or analog signal drift |
| Maintenance | ⚠️ Reactive — the switch fails without prior warning | ✅ Predictive — deterioration is detected before failure |
| Network protocols | ⚠️ Analog signal only — no industrial network integration | ✅ PROFINET, EtherNet/IP, EtherCAT — native industrial network integration |
| Relative cost | ✅ Lower initial cost — for facilities without an industrial network | Higher than the switch — justified by predictive diagnostics and simplified wiring |
Main applications of the ON-OFF automation kit where IO-Link also provides predictive diagnostics
- Automation of shut-off and isolation valves in facilities with a PROFINET, EtherNet/IP, or EtherCAT network: The IO-Link ON-OFF kit automates shut-off valves with digital position confirmation to the PLC. It is also the correct specification when the control architecture uses an industrial network and predictive diagnostics are required without additional wiring.
Compatibility with PROFINET, EtherNet/IP, and EtherCAT also allows it to be integrated into any existing control architecture.
- Automatic filling, emptying, and CIP sequences where the PLC needs position confirmation before proceeding: In automatic process sequences, the PLC advances to the next stage only when it confirms that the valve has reached the correct position. The kit transmits that confirmation digitally, along with diagnostic data that allows detection if the valve took longer than normal to reach the commanded position.
Applications in automatic sequences, pharmaceuticals, and modernization where ON-OFF with IO-Link also meets specific requirements
- Modernization of manual valves or those with conventional limit switches to automatic control with diagnostics: When converting manual valves or those with mechanical switches to automatic control with digital diagnostics, this kit is the lowest-cost option. The simplified wiring also reduces modernization costs compared to installing a limit switch with additional independent feedback wiring.
- Pharmaceutical and food industries where digital traceability of valve position is a GMP validation requirement: In pharmaceutical and food processes, position, temperature, and operating hours data are recorded in the control system for auditing and validation. Predictive diagnostics ensure, since the positioner's parameters are continuously monitored, that the instrument operates within the validated limits at all times.
- Facilities with a PROFINET, EtherNet/IP, or EtherCAT network where direct integration of the automation kit into the network is a requirement: In modern facilities with industrial network infrastructure, this ON-OFF kit integrates directly through its IO-Link master. It requires no additional converters. Consequently, the positioner appears in the control system as just another device on the network, with all its diagnostic data accessible from the control room.
For the full range of automation kits, see automation kits collection →