Single-Acting Linear Pneumatic Positioner | Signal 0.2-1 bar | IP66 | No Electrical Signal | Aluminum
Pickup availability could not be loaded
Single-Acting Linear Pneumatic Positioner — 0.2-1 bar Input Signal, No Electrical Signal, IP66, Aluminum Body
Cematic's single-acting linear pneumatic positioner positions linear actuators for globe and diaphragm valves using only a pneumatic input signal — with no electrical connection.
Unlike electro-pneumatic positioners that require a 4-20 mA signal, this model receives the signal directly from the pneumatic controller in the 0.2-1 bar range and converts it into the pilot pressure for the actuator.
It is the correct specification for legacy pneumatic control systems, for installations where the absence of an electrical signal is a design requirement, or when the budget does not justify an electro-pneumatic positioner. Its aluminum body with IP66 protection also ensures durability in damp environments.
Pure pneumatic — why this positioner does not need an electrical signal even when operating in classified areas
The absence of an electrical signal is the main differentiator of this positioner compared to the rest of the catalog. The following situations describe where this feature is the correct specification, as an electrical signal is not always available or always advisable to use:
- Plants with legacy pneumatic control systems — since the controller emits a 0.2-1 bar signal directly: Many older industrial installations use pneumatic controllers that emit a signal in the 0.2-1 bar (3-15 psi) range. This positioner connects directly to that signal, so it does not require additional converters. Therefore, it is the simplest and most economical option for those installations.
- Installations where an electrical signal is not available in the field — since the control network is entirely pneumatic: At some process points far from the control system, it is more economical to run air piping than electrical wiring. The pneumatic positioner also allows the control system to be extended to those points without electrical infrastructure.
Cases where the absence of an electrical signal is also a design or safety requirement
- Intrinsic safety requirements where it is preferred to eliminate any electrical component, since the pneumatic positioner does not generate current: In some installations, regulations or design criteria prefer to eliminate any source of electrical power in the process area.
The pure pneumatic positioner does not generate or conduct electrical current, therefore it is intrinsically safe by design without the need for additional Ex certification.
- Projects with budget constraints where an electro-pneumatic positioner is unnecessary, since the pneumatic signal is already available: When the control system already has a 0.2-1 bar pneumatic signal and no diagnostic functions or digital communication are required, this positioner is the lowest-cost option.
The savings compared to an electro-pneumatic positioner are significant, even though the functionality is lower.
Single-acting — what it means for the positioner and when it is the correct configuration for the actuator
Single-acting defines the behavior of the assembly in response to a variation in the pilot signal. It is the most important criterion when specifying the positioner, as it must match the type of actuator:
- Single-acting — correct when the actuator uses air to move in one direction and a spring to return, since the positioner only controls one chamber: The single-acting positioner regulates the pressure in the actuator's active chamber. Therefore, it is the standard configuration for globe valves with single-acting diaphragm actuators.
- Not correct for double-acting actuators — since those require control in both chambers: If the actuator is double-acting, the single-acting positioner cannot control it correctly. In those cases, a double-acting pneumatic positioner must be specified. Although the difference may seem minor, specifying the wrong type of action results in loss of control.
Technical specifications that define the limits of the single-acting linear pneumatic positioner
| Parameter | Value |
|---|---|
| Positioner type | Pure pneumatic — no electrical signal |
| Compatibility | Single-acting pneumatic linear actuators |
| Input signal | 0.02~0.1 MPa (0.2~1 bar) — pneumatic signal |
| Supply pressure | 0.14~0.7 MPa (1.4~7 bar) |
| Air connection | 1/4" NPT |
| Pressure gauge connection | 1/8" NPT |
| Air consumption | 2.5 LPM (at 0.14 MPa) |
| Flow capacity | 80 LPM (at 0.14 MPa) |
| Body material | Aluminum |
| Enclosure protection | IP66 |
| Operating temperature | -20 °C to +70 °C |
| Electrical signal required | None |
| SKU | PPNL01 |
Pneumatic positioner vs. electro-pneumatic — comparison table to select the correct one since the control system determines which to use
| Criterion | Pneumatic positioner ← This product | Electro-pneumatic positioner (4-20 mA) |
|---|---|---|
| Input signal | ✅ Pneumatic 0.2-1 bar — no electrical wiring | Electrical 4-20 mA — requires wiring and power supply |
| Compatible with pneumatic controllers | ✅ Yes — direct connection without I/P converter | ❌ No — requires current-to-pressure converter |
| Compatible with DCS/PLC with 4-20 mA output | ❌ Not directly — requires P/I converter | ✅ Yes — direct connection to the DCS analog output |
| Remote diagnostics | ❌ Not available | ⚠️ Only with HART smart positioner |
| Safety in classified areas | ✅ No electrical sources — intrinsically safe by design | Requires Ex certification for classified areas |
| Relative cost | ✅ Lowest in the positioner catalog | Higher — justified when an electrical control system is available |
| Correct application | ✅ Legacy pneumatic control systems or where no electrical signal is available | Modern DCS/PLC systems with 4-20 mA analog output |
Main applications of the single-acting linear pneumatic positioner where no electrical signal is available
- Globe valve control in plants with legacy pneumatic control systems where the signal is 0.2-1 bar: In industries such as chemical, petrochemical, and energy with control systems installed before the 90s, the controller emits a 0.2-1 bar pneumatic signal directly. The pneumatic positioner also connects to that signal without additional converters. It is also the lowest-cost option to modernize the calibration of those valves without replacing the control system.
- Water and wastewater treatment installations where the pneumatic signal is the existing standard: In treatment plants with established pneumatic infrastructure, this positioner integrates directly into the system without the need to add electrical wiring. The IP66 also ensures the necessary resistance in damp environments and vapors typical of those installations.
Applications in areas without electrical signal and modernization of existing pneumatic installations
- Industrial processes where it is required to eliminate the electrical signal in the field for design reasons: In some plants, the design criterion establishes that there should be no active electrical components in certain process areas. The pneumatic positioner meets that requirement: it operates only with compressed air without electrical power sources.
- Modernization of manual valves in installations with available compressed air piping: When an installation has a compressed air network and a pneumatic controller, converting a manual valve to proportional control with this positioner is the lowest-cost option. It therefore does not require electrical infrastructure or additional Ex certification for the area.
- Power generation and steam systems where linear positioning without electricity is an advantage: In power plants with linear actuators in steam and boiler water lines, this positioner controls the valve from the existing pneumatic control system. The air consumption of 2.5 LPM, finally, is very low and does not represent a significant load for the plant compressor.
For the complete range of positioners, see positioner collection →